Control Damper
Series 9000 BF: Thermally Broken Frame
- Blades are thermally insulated through polyurethane foam injection
- With Thermal Break Technology frame
- Thermally broken frames, coupled with thermally insulated and thermally broken blades, combat condensation and freeze-up.
- Creates a thermal barrier between outside air temperature and desired interior temperature
- High thermal efficiency contributes to energy savings.
- Tamco silicone seals provide outstanding dynamic fatigue resistance, ensuring consistent minimal leakage rate performance and sealing longevity.
- Tamco’s dual bearing linkage system is self-sealing, self-lubricating, and non-absorbent, resulting in a maintenance-free performance.
Caution: Never use any lubricants, such as grease or silicone, on Tamco dampers.
- Applications
- Leakage
- Options
- Profiles
- Documents
Series 9000 BF Thermally Insulated, Control Damper with Thermally Broken Frames:
- In conditions of high relative humidity, where condensation and freeze-up are a concern
- When there are extreme temperature differentials
- If the damper is closed approximately 80% of the time
- For air intake and exhaust
- Where low leakage, maintenance-free dampers are required for ducted or non-ducted outside walls, or plenums
- This grade of silicone and its leakage resistant properties are virtually unaffected by cold winter temperatures. The operating temperature range is -40°F (-40°C) to 212°F (100°C).
Leakage Class 1A at 1 in. w.g. (0.25 kPa) static pressure differential. Standard air leakage data is certified under the AMCA Certified Ratings Program.
Damper Width Inches (mm) | 1 in. w.g.0.25 kPa | 4 in. w.g. 1.0 kPa | 6 in. w.g.1.5 kPa | 8 in. w.g.2.0 kPa |
---|---|---|---|---|
0.0 to 12.0 (0 to 305) | 1A | 1 | 1 | 1 |
12.1 to 36.0 (306 to 915) | 1A | 1 | 1 | 1 |
36.1 to 48.0 (916 to 1220) | 1A | 1 | 1 | 1 |
48.1 to 60.0 (1221 to 1524) | 1A | 1 | n/a | n/a |
ECT – Extreme Cold Temperature Option:
- Specifically designed for extreme cold temperatures, below -40°F (-40°C) and down to -100°F (-73°C)
MR – Moisture Resistance Option:
- Excellent cold climate solution for applications where dampers are exposed to extended periods of high humidity or high moisture, such as water treatment facilities, municipal pools, greenhouses and cooling towers.
- Cost effective alternative to the Salt Water Resistance option for applications where salt spray is not a concern.
Please click the option above that is most applicable to you for more information.
Recommendation: In applications where the humidity level is unusually elevated, or where there are extremely high levels of dust and dirt particles, Tamco recommends that the damper linkage and bearing system should be cleaned once a year. This can be done by blowing away dust using compressed air. If needed, a domestic-strength steam cleaner can be used to loosen dirt, which can then be blown out with compressed air, along with any remaining water droplets.
SP – Standard profile
- Manufactured with 4” (101.6 mm) deep frames
- Manufactured with blades that are a maximum 6” (152.4 mm) deep.
NP – Narrow Profile
- Manufactured with 4” (101.6 mm) deep frames
- Manufactured with blades that are a maximum of 4” (101.6 mm) deep.
- Space saving narrow profile is ideal for space restrictive installations.
Series 9000 BF Specifications and Performance Data
Download PDF Document
Download PDF Document (French)
Series 9000 BF Suggested Specifications
Download Microsoft Word Document
Download Microsoft Word Document (French)
Tamco Aluminum Damper Installation Guidelines
Download PDF Document
Download PDF Document (French)
Tamco Aluminum Control Damper Schedule
Download Microsoft Excel Sheet
Download Microsoft Excel Sheet (French)