• Series 7600 CW: Internally Counterweighted Heavy-Duty

Backdraft Damper

Series 7600 CW: Internally Counterweighted Heavy-Duty

  • Each blade is fitted with a fixed internal counterweight.
  • Counterweights are provided to accelerate opening of blades, and to allow blades to achieve the full open position at lower pressures and airflow velocities.
  • Tamco heavy-duty backdraft dampers are constructed with robust components to withstand up to 12” w.g. (3.0 kPa) of static pressure and velocities up to 3500 fpm (17.8 m/s).
  • Blades are designed with a rounded head. This reduces pressure loss.
  • Tamco’s dual bearing linkage system is self-sealing, self-lubricating, and non-absorbent, resulting in a maintenance-free performance.
  • Silicone seals are provided as standard to ensure sealing longevity and remain flexible down to -40° F/C.
  • For horizontal and vertical airflow operation

Caution: Never use any lubricants, such as grease or silicone, on Tamco dampers.

FIND A REP

  • Applications
  • Options
  • Profiles
  • Documents

Series 7600 CW Counterweighted Heavy-Duty, Backdraft Damper:

  • Used to accelerate opening of blades and designed to allow opening at lower pressures and airflow velocities
  • Specifically designed for installations requiring a heavy-duty backdraft damper, subjected to elevated velocities and operating pressures
  • Recommended for use in high-pressure isolation systems, air handling units, gen sets, and fan inlet or fan outlet locations

ET – Elevated Temperature Option:

  • Suitable for high heat environments where temperatures may reach as high as 300°F (149°C),and where UL regulated control dampers are not a requirement
  • For use in back-up generator stations, where excessive heat may be an issue
  • For test laboratory applications, wherever high-heat conditions may exist
  • A practical solution in mildly acidic applications, where Celcon bearings may not withstand environmental conditions

MR – Moisture Resistance Option:

  • Suitable for applications where dampers are exposed to extended periods of high humidity or high moisture, such as water treatment facilities, municipal pools, and greenhouses
  • Cost effective alternative to the Salt Water Resistance Option for applications where salt spray is not a concern

SW – Salt Water Resistance Option:

  • Ideally suited for coastal climates
  • Recommended for inland applications, where tire spray from winter-salted roads have been known to corrode dampers installed in close proximity to roads or highways

Please click the option above that is most applicable to you for more information.

SP – Standard profile

  • Manufactured with 4” (101.6 mm) deep frames
  • Manufactured with blades that are a maximum 6” (152.4 mm) deep.

Series 7600 CW Submittal and Performance Data

Download PDF Document
Download PDF Document (French)

Series 7600 CW Suggested Specifications

Download Microsoft Word Document
Download Microsoft Word Document (French)

Tamco Heavy-Duty Backdraft Damper Installation Guidelines

Download PDF Document
Download PDF Document (French)

Heavy-Duty Backdraft Damper Schedule

Download Microsoft Excel Document
Download Microsoft Excel Document (French)